D90Plus – Legacy
Manufacturing for this product has been discontinued. As an alternative, please refer to the D60 with Firmware 7.7 or newer and User Interface Option
Manufacturing for this product has been discontinued. As an alternative, please refer to the D60 with Firmware 7.7 or newer and User Interface Option E: 7” Graphical Front Panel Display.
The D90Plus is a sub-cycle line distance protection system and bay controller suitable for protecting transmission lines and cables including lines equipped with series compensation. The D90Plus supports dual-breaker applications and can be used for single or three-pole tripping. The D90Plus supports different teleprotection schemes, including DCB, DCU, POTT, Hybrid POTT, and PUTT. The D90Plus also provides synchrophasor measurement over Ethernet per IEEE C37.118.
Key Benefits
- Secure sub-cycle distance protection
- CCVT filter improves performance without intentional delays or reduced fault coverage
- Superior phase selection algorithm ensures secure high-speed single-pole tripping
- Reliable and secure protection on lines equipped with series compensation
- Color HMI with metering, event records and control
- Fault and disturbance recording at up to 128 samples/cycle
- Built-in phasor measurement unit streaming synchrophasors as per IEEE C7.118
- Configurable alarm annunciator eliminates the need for separate annunciator panel
Applications
- Overhead lines including series-compensated lines and underground cables
- Backup protection for generators, transformers and reactors
- Single and dual-breaker circuits requiring single/three-pole autoreclosing and independent synchrocheck supervision
- Circuits with in-zone power transformers - secure application with Capacitively-Coupled Voltage Transformers (CCVTs)
D90Plus – Legacy
Manufacturing for this product has been discontinued. As an alternative, please refer to the D60 with Firmware 7.7 or newer and User Interface Option
Manufacturing for this product has been discontinued. As an alternative, please refer to the D60 with Firmware 7.7 or newer and User Interface Option E: 7” Graphical Front Panel Display.
The D90Plus is a sub-cycle line distance protection system and bay controller suitable for protecting transmission lines and cables including lines equipped with series compensation. The D90Plus supports dual-breaker applications and can be used for single or three-pole tripping. The D90Plus supports different teleprotection schemes, including DCB, DCU, POTT, Hybrid POTT, and PUTT. The D90Plus also provides synchrophasor measurement over Ethernet per IEEE C37.118.
Key Benefits
- Secure sub-cycle distance protection
- CCVT filter improves performance without intentional delays or reduced fault coverage
- Superior phase selection algorithm ensures secure high-speed single-pole tripping
- Reliable and secure protection on lines equipped with series compensation
- Color HMI with metering, event records and control
- Fault and disturbance recording at up to 128 samples/cycle
- Built-in phasor measurement unit streaming synchrophasors as per IEEE C7.118
- Configurable alarm annunciator eliminates the need for separate annunciator panel
Applications
- Overhead lines including series-compensated lines and underground cables
- Backup protection for generators, transformers and reactors
- Single and dual-breaker circuits requiring single/three-pole autoreclosing and independent synchrocheck supervision
- Circuits with in-zone power transformers - secure application with Capacitively-Coupled Voltage Transformers (CCVTs)
| ||||||||
| ||||||||
| |||||||
| |||||||
| |||||||
| |||||||
|
| |||||
| |||||
|
| ||||||
| ||||||
Enhanced Sub-Cycle Distance Protection - Sub-cycle quadrilateral characteristic added for applications where this characteristic is preferred over the mho characteristic - True digital CCVT filter to remove voltage transients introduced and provide accurate voltage information for distance protection – requires only three relay settings | |
Software Ease-of-Use: - EnerVista Viewpoint Engineer now available for graphical configuration of Protection and Automation FlexLogic™ | |
Security Enhancements - Enabling NERC CIP compliance: - Dual permission access requiring live permission from both the user and from SCADA operators before settings can be changed or commands can be given to the relay - Remote and local setting and control passwords - Configurable lockout responses to unsuccessful password access attempts - Successful password access logged in events record - Logging of user commands in the security audit trail report creates a record and sequence of events log for troubleshooting and security auditing | |
| New and Enhanced Communications Capabilities - PRP as per IEC62439-3 |
High-Density I/O Options: - New high density I/O option modules featuring either 23 optically isolated inputs or 12 Form-A outputs - Ideal for applications like bay control and monitoring, where a large number of additional I/O are required |