Kelman TRANSFIX
The TRANSFIX is an 9-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.
Benefits
- Transformer faults detected in their infancy, minimizing costly unplanned outages and equipment failure.
- Remote assessment of fault type and severity
- Transformer output optimized safely, maximizing your assets.
- Designed for field use – global installation by almost all major utilities.
- Photo Acoustic Technology – no costly consumables/calibration gases required.
Features
- DGA & Water – Nine gases (hydrogen, methane, ethane, ethylene, acetylene, carbon monoxide, carbon dioxide, nitrogen and oxygen) plus moisture.
- Inputs/Outputs for additional sensors including load and oil temperature.
- Hourly Sampling – Real-time DGA results down to once per hour.
- Communication Options – Extensive local and remote communications options.
- Alarm Settings – Sophisticated programmable alarm system.
- Acceleration of sampling rate – automatic increase in sampling rates if gas concentrations exceed caution or alarm settings.
- Minimal Maintenance – Reduces expense and inconvenience for user.
- Easy Installation – Simple, straightforward procedures.
Applications
- Medium and large sized transformers.
- Medium/High/Critical risk and/or consequence of failure.
- Generation, Transmission and industrial transformers.
- Complete transformer monitoring and diagnostics.
Image Gallery
To view and download high resolution images of our products, please click on the thumbnails below.
Kelman TRANSFIX
The TRANSFIX is an 9-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.
Benefits
- Transformer faults detected in their infancy, minimizing costly unplanned outages and equipment failure.
- Remote assessment of fault type and severity
- Transformer output optimized safely, maximizing your assets.
- Designed for field use – global installation by almost all major utilities.
- Photo Acoustic Technology – no costly consumables/calibration gases required.
Features
- DGA & Water – Nine gases (hydrogen, methane, ethane, ethylene, acetylene, carbon monoxide, carbon dioxide, nitrogen and oxygen) plus moisture.
- Inputs/Outputs for additional sensors including load and oil temperature.
- Hourly Sampling – Real-time DGA results down to once per hour.
- Communication Options – Extensive local and remote communications options.
- Alarm Settings – Sophisticated programmable alarm system.
- Acceleration of sampling rate – automatic increase in sampling rates if gas concentrations exceed caution or alarm settings.
- Minimal Maintenance – Reduces expense and inconvenience for user.
- Easy Installation – Simple, straightforward procedures.
Applications
- Medium and large sized transformers.
- Medium/High/Critical risk and/or consequence of failure.
- Generation, Transmission and industrial transformers.
- Complete transformer monitoring and diagnostics.