EPM 7000 Power Quality Meter
Power Quality and Energy Cost Management
Power Quality and Energy
Cost Management
The EPM 7000 provides continuous metering of three-phase systems with waveform and data logging. It performs energy measurements with 0.2% accuracy and supports optional Ethernet, relay, status, and analog output communication modules. This flexible meter can be used for a wide range of high accuracy applications including disturbance recording and power quality studies.
The EPM 7000T is a transducer configuration that comes without a display and has a DIN rail mount.
GE Grid Solutions has discontinued sales of EPM 7000T. As an alternative, please refer to the EPM7000PT .
- Power quality metering with historical data logging
- Waveform Capture, up to 512 samples/cycle
- Optional 100BaseT Ethernet (Modbus/DNP or Modbus/IEC 61850)
- Multiple communication ports for integration with DCS and SCADA systems
- Standard RS485 Modbus (DNP 3.0 and Modbus RTU or ASCII)
- Four quadrant energy & power monitoring for feeders, transformers, reactors and generators
- Monitoring of LV and MV industrial power systems, motor control centers & distribution utilities
- Energy monitoring for commercial buildings
- Metering device for Power Quality & Load Studies (data logging option required)
- Equipped with Front Mounted IrDA Communications port
- Rear mounted RS485 serial interface which supports Modbus, and DNP 3.0
- KYZ pulse outputs that are mapped to absolute energy.
- Two expansion slots used for field replaceable I/O cards
EPM 7000 Power Quality Meter
Power Quality and Energy Cost Management
Power Quality and Energy
Cost Management
The EPM 7000 provides continuous metering of three-phase systems with waveform and data logging. It performs energy measurements with 0.2% accuracy and supports optional Ethernet, relay, status, and analog output communication modules. This flexible meter can be used for a wide range of high accuracy applications including disturbance recording and power quality studies.
The EPM 7000T is a transducer configuration that comes without a display and has a DIN rail mount.
GE Grid Solutions has discontinued sales of EPM 7000T. As an alternative, please refer to the EPM7000PT .
- Power quality metering with historical data logging
- Waveform Capture, up to 512 samples/cycle
- Optional 100BaseT Ethernet (Modbus/DNP or Modbus/IEC 61850)
- Multiple communication ports for integration with DCS and SCADA systems
- Standard RS485 Modbus (DNP 3.0 and Modbus RTU or ASCII)
- Four quadrant energy & power monitoring for feeders, transformers, reactors and generators
- Monitoring of LV and MV industrial power systems, motor control centers & distribution utilities
- Energy monitoring for commercial buildings
- Metering device for Power Quality & Load Studies (data logging option required)
- Equipped with Front Mounted IrDA Communications port
- Rear mounted RS485 serial interface which supports Modbus, and DNP 3.0
- KYZ pulse outputs that are mapped to absolute energy.
- Two expansion slots used for field replaceable I/O cards
The EPM 7000 meter provides revenue class (0.2%) three phase power metering with optional Ethernet, relay, status, and analog output communication modules. This flexible meter can be used for a wide range of high accuracy applications including disturbance recording and power quality studies.
EPM 7000 can easily be mounted in a panel for generator monitoring, substation automation, power quality studies, data recording and more. The meter can also provide data to RTUs, PLCs and other control devices.
The EPM 7000 is a highly accurate meter providing 0.1% accuracy for Voltage and Current. The unit’s real-time clock provides time stamping of all logs as they are created. Up to 2 MB of data can be logged for analysis of historical trends, limit alarms, I/O changes and sequence of events.
|
Universal Voltage and Current Inputs
This meter allows voltage input measurements 20 Volts to 576 Volts Line to Neutral and up to 721 Volts Line to Line. This ensures proper meter safety when wiring directly to high voltage systems. The unit will perform to specification on 69 Volt, 120 Volt, 230 Volt, 277 Volt and 347 Volt power systems.
Unique Current Input Connections
EPM 7000 meter uses two current input wiring methods.
|
The EPM 7000 is equipped with a virtual firmware based switch that allows feature upgrades through communications even after installation. This allows you to optimize your metering investment. Begin with a standard meter and upgrade it with more functionality as new features are needed, such as data logging, waveform capture or more memory. The tables below describe the feature sets of each of the software and waveform options.
Front Mounted IrDA
All EPM 7000 meters come equipped with Front Mounted IrDA Communications port. This eliminates the need for a communications cable when the technician has an IrDA-equipped PC or a PDA with COPILOT EXT software. The meter can be set-up and programmed through the IrDA connection.
Rear Mounted Serial Port with KYZ Pulse
The RS485 serial interface supports Modbus, and DNP 3.0 at baud rates ranging from 9600 to 57.6K. Also supported are KYZ pulse outputs that are mapped to absolute energy.
Expandable I/O and Communications Capabilities
EPM 7000 meters have two expansion slots used to accept new I/O cards. These slots can be equipped at the factory or in the field. The meter auto-detects installed I/O cards. Up to two cards of any type may be used per meter.
|
The EPM 7000 with Ethernet (E1,E2 options) includes a secure web server that is viewable from a variety of web browsers. The web server supports multiple simultaneous connections to view the following information:
- Voltage and Current Reading
- Power and Energy Readings
- Power Quantity Information
- General Meter Information
Simultaneous Data Connections
GE Grid Solutions has discontinued sales of EPM 7000T. As an alternative, please refer to the EPM7000PT .
The transducer configuration comes without a display and has a DIN rail mount. It’s ideal for use in switchgear retrofit applications where access to the meter face and display is not necessary, and where budgets are a large consideration.
- EPM 7000 Power Meter without display, DIN mount
- Mounts directly in ANSI C39.1 (4” round form) or and IEC 92mm DIN square form
- Uses minimal panel space with 4.25” panel depth
- 0.2% Watt-Hour Accuracy and waveform capture at up to 512 samples/cycle
- Up to 4MB of data logging
- Field Replaceable I/O modules
Expanding existing switchgear or installing new metering capability can be challenging due to space limitations, downtime and installation and equipment costs. GE's Multilin Meter Enclosure is a pre-wired configured, economical solution for both retrofit expansions and small scale meter installations that allows the expansion of existing switchgear capability without expensive and time-consuming design.
When ordered as a meter option the enclosure provides a factory pre-wired, installation-ready metering solution that further drives energy cost savings, by enabling the measurement of key energy usage information along multiple metering points for new or existing systems.
Ordering the enclosure is simple when selected as an option during meter configuration, ensuring correct pre-wired meter-compatible delivery.
| ||||||||