Duration
4 Days
Who should attend?
Engineers and technicians involved in design, study, modifications and maintenance
What will I learn from this course?
  • Design a high voltage electrical installation
  • Estimate the value of the short-circuit currents
  • Select the electric equipment and cables
  • Improve the dialogue with people operating on site
Topics

Steps of the design of an installation

  • Standards according to the country: NFC 13-100 and NFC 13-200 (France), CIE (international), Electricity code of Quebec, etc…
  • List of equipment
  • Selection of the structure
  • Flow line diagram
  • Selection of the neutral systems: isolated neutral, earth neutral

Voltage and current transformers 

Characteristics of the equipment 

Characteristics of the sources

  • Grids, transformers, groups

Selection of the electric cables

  • Dimensioning criteria

Selection of the equipment

  • Disconnectors, switches, contactors, fuses, circuit breakers

Reminders of the short circuit current estimation

  • The source is a transformer
  • The source is a generator group

Neutral systems in industrial grids

  • Study of the “isolated neutral” and "neutral Earthing resistors" systems

Reminders of the industrial grids protection

  • “phases” default protection plan
  • Earth” default protection plan

Reminders of the protection of distribution transformers 

Case study

  • Design of one part of a plant: selection of the equipment, comparison of the different solutions

Learning path

PrerequisitesA2112Next step
A0201
2-years University technological diploma
or completion
40% Case Study
60% Theoretical
D2102
This training can be provided on site at your own convenience. Customized to customer needs (troubleshooting, grid modification or extension).

High voltage industrial installations - Design (A2112)

Duration
4 Days
Who should attend?
Engineers and technicians involved in design, study, modifications and maintenance
What will I learn from this course?
  • Design a high voltage electrical installation
  • Estimate the value of the short-circuit currents
  • Select the electric equipment and cables
  • Improve the dialogue with people operating on site
Topics

Steps of the design of an installation

  • Standards according to the country: NFC 13-100 and NFC 13-200 (France), CIE (international), Electricity code of Quebec, etc…
  • List of equipment
  • Selection of the structure
  • Flow line diagram
  • Selection of the neutral systems: isolated neutral, earth neutral

Voltage and current transformers 

Characteristics of the equipment 

Characteristics of the sources

  • Grids, transformers, groups

Selection of the electric cables

  • Dimensioning criteria

Selection of the equipment

  • Disconnectors, switches, contactors, fuses, circuit breakers

Reminders of the short circuit current estimation

  • The source is a transformer
  • The source is a generator group

Neutral systems in industrial grids

  • Study of the “isolated neutral” and "neutral Earthing resistors" systems

Reminders of the industrial grids protection

  • “phases” default protection plan
  • Earth” default protection plan

Reminders of the protection of distribution transformers 

Case study

  • Design of one part of a plant: selection of the equipment, comparison of the different solutions

Learning path

PrerequisitesA2112Next step
A0201
2-years University technological diploma
or completion
40% Case Study
60% Theoretical
D2102
This training can be provided on site at your own convenience. Customized to customer needs (troubleshooting, grid modification or extension).