High Voltage Direct Current (HVDC) systems enable utilities to move more power further, efficiently integrate renewables, interconnect grids, and improve network performance. HVDC systems utilize power electronics technology to convert AC and DC voltage and are ideal for supporting existing systems or building new power highways.
GE Vernova provides solutions that offer grid operators the ability to provide reactive power support, enhance controllability, improve stability and increase power transfer capability of AC transmission systems.
Substation and Electrical Infrastructure Projects for Utility and Industrial Customers.
GE Vernova offers solutions for a variety of substation projects and applications, including Modular Substation Automation Systems, utility and industrial substation projects, as well as DC substation solutions.
Energy storage is the backbone of the modern power system, delivering reliable, high quality energy for utilities, data centers, industry, and communities. It unlocks the full potential of renewable and clean energy, ensuring critical operations stay continuously online in an always on economy while accelerating the electrification of everything.
Integrated electrical systems provide energy where the grid doesn’t reach, meeting increasing power demands while improving resilience and efficiency.
The energy landscape today is changing, this is being led by the current industry trends of Decarbonization, Digitization, Decentralization and Electrification. Discover how GE Vernova is working with utility, consumer and industrial customers to design and deploy tailored Microgrid and Distributed Energy Resource (DER) Management solutions.
GE Vernova delivers advanced power stability and flexibility solutions that help utilities and electro-intensive industries meet grid connection requirements and evolving regulatory standards. Our portfolio is designed to enhance grid performance, compliance, and resilience.
Innovations to Decarbonize the Electrical Grid. GRiDEA is our portfolio of decarbonization solutions that empower grid operators to address their net-zero objectives.
GE Vernova offers a wide range of transformer solutions for the utility, industrial, commercial, residential and energy markets. These solutions feature flexible, reliable and robust designs to support a wide range of applications. With units operating in some of the most demanding electrical environments around the world, We design and delivers transformer solutions that provide among the highest level of performance and reliability to meet rigorous operating requirements.
GE Vernova provides GIS solutions from 50 kV to 800 kV, along with secondary products to maximize switchgear and network operation. The portfolio includes a full range of SF₆ GIS as well as g³ (SF₆-free) GIS at 145 kV and 420 kV voltage levels for utilities and industries worldwide.
GE Vernova is one of the top circuit breaker suppliers in the world. Our products include a range of live tank circuit breakers (up to 800 kV), dead tank circuit breakers (up to 550 kV), as well as hybrid and compact switchgear assemblies. We also provide solutions for power generation applications with our generator circuit breakers for installations up to 1,500 MW.
GE Vernova is a global market leader for disconnectors (disconnect switches) since 1960, with 8 product facilities in 7 countries and hundreds of thousands installations in more than 130 countries around the world. The portfolio includes disconnectors for AC applications (up to 1,200 kV), for DC applications (up to 1,000 kV) and for railway applications. We also offer power connectors to connect two or more conductors for a continuous electrical path.
GE Vernova is an industry leader in the design and manufacturing of high, medium and low voltage instrument transformers. With more than 100 years of experience, We offer a broad array of standard and high accuracy models for revenue metering and system protection applications. The portfolio of instrument transformers ranges from low voltage at 600 V suitable for industrial and high accuracy revenue metering, all the way up to high voltage at 1,200 kV. The portfolio also includes line traps and digital instrument transformers.
For a century, utilities have relied on us to deliver electrical products and services to meet their quality, durability and performance needs. Our capacitor and reactor product lines are an integral part of our portfolio. GE Vernova provides power capacitors that meet ANSI, IEEE and IEC standards, and our low voltage capacitors are UL listed. Ratings range from 1 kvar to 500 MVAR, and from 240 volts to 500 KV.
GE Vernova provides a broad range of bushings and surge arresters to help protect electrical assets. The bushings portfolio includes AC and DC solutions that enable long life, high reliability and installation flexibility. GE Vernova’s Tranquell surge arresters are ideal for distribution and EHV applications up to 612kV, and are available as polymer and porcelain station and intermediate class IEEE/ANSI C62.11.
Our SF₆-free switchgear range features the same ratings and same dimensional footprint as the state-of-the-art SF₆ equipment, with a drastically reduced carbon footprint.
Drawing on more than 125 years of engineering heritage, GE Vernova offers rotating machine solutions designed for performance, reliability, and industrial scale.
Digital Native Products are not just an evolution of existing switchgear but a transformation in how GE Vernova conceives and builds primary equipment for the grid.Digital Native Products are designed with digital capabilities embedded, enabling a compact and standard design and are mechanically engineered to reach the accuracy required by advanced monitoring and control solutions. Products are ready to connect and operate quickly and effectively. Discover the various monitoring and control solutions that can be incorporate in Digital Native Products.
GE Vernova delivers advanced power electronics solutions that help electrify industries, optimize performance, and improve reliability. Our integrated portfolio supports critical applications with the technology and services needed to power a more efficient and sustainable future.
Safely and securely accelerate operations with tailored automation systems that enhance control, reduce risk and add value.
GridBeats™ is a portfolio of software-defined automation solutions for grid digitalization. The portfolio is designed to enable utilities and industrial customers to ensure a stable, efficient energy supply amidst the growing integration of renewable energy sources and aging infrastructure.
GE Vernova's comprehensive portfolio of solutions for implementing and managing a substation.
GE Vernova’s Protection, Control, and Metering solutions deliver precise, high-performance automation for today’s evolving grid. From advanced relays to multifunction meters, our portfolio helps utilities enhance reliability, streamline operations, and accelerate the energy transition. Backed by decades of expertise and global reach, we provide the products to protect assets, optimize performance, and power a more sustainable future.
GE Vernova offers a wide range of solutions to monitor and manage critical assets on the electrical grid, detect and diagnose issues and provide expert information and services to customers. Our asset monitoring and diagnostics portfolio includes solutions for single- and multi-gas transformer DGA, enhanced transformer solutions and switchgear monitoring, as well as software and services.
GE Vernova's Critical Infrastructure Communications (CIC) solutions deliver secure, resilient, and scalable networks that ensure operational continuity in even the most demanding environments. We help customers reduce downtime, enhance safety, and improve situational awareness through end-to-end communication solutions built for reliability and performance. This translates into greater efficiency, regulatory compliance, and peace of mind for mission-critical operations.
The collection of required asset condition data from the field on a large scale for GE Vernova and 3rd party electrical equipment is a key step in building a robust Asset Performance Management strategy. Grid Services specialists are constantly evaluating and implementing new innovative inspection technologies applying strict processes and methods. The digital inspections methods are designed to improve the efficiency of data collection, oil analysis and online monitoring. All new approaches to capture data are integrated into the EnergyAPM ecosystem for automatic data transfer.
GE Vernova's Asset Lifecycle Management services combine a large set of methodologies to collect condition data off and online, consulting and asset optimization services using digital technology to improve the monitoring, recording and analysis of asset operations and predict asset behavior.
GE Vernova’s innovative and high-quality services help maintain and optimize high-voltage electrical assets throughout their entire lifecycle. Leveraging the design and manufacturing knowledge of our engineers, the customized service solutions ensure substations and networks perform as planned. Experts deliver services for applications across the power system, keeping assets up-to-date, safe, reliable and efficient while improving customers’ return-on-investment.
GE Vernova provides a full range of services & support tailored to meet a broad range of power system needs across utility and industrial applications. With deep domain knowledge and industry expertise GE Vernova’s service application engineers and technical specialists can help plan, design, operate, maintain, and modernize your protection, control, monitoring and automation systems.
GE Vernova provides comprehensive services throughout the systems lifecycle. The services can be provided by our local team and with the support of our global Competence Centers when the equipment is installed, during the warranty period and beyond.
Our certified laboratories enable manufacturers and customers leverage deep domain expertise and advanced testing and analysis facilities to develop enhanced high-voltage products, certify their capabilities before market introductions and apply preventive maintenance to avoid unexpected interruptions and ensure the reliability of your operations.
Our product range covers from the smallest medium voltage electrical rotating machines to custom made large units, up to 80 MW, as well as their operating and protection controls. Our aftermarket fleet of over 70,000 rotating machine assets, spread over 150 countries worldwide, that we’ve served for a century. Our experience in all energy, industry and transportation sectors is broad and deep.
We connect the physical world with data to proactively detect and forecast the behavior of your assets by offering Digital Suite, Service 360 & Cyber security.
Our MV drives portfolio ranges from 100 kW to more than 100 MW and from 3.8 up to 13.8 kV voltages. It allows for higher operating efficiency, power availability, plant throughput, operational precision, and process yield. Our LV drives portfolio ranges from of 0.25kW to more than 6MW and from 270 up to 900VAC voltages which includes fully and doubly fed wind converters, marinized drives, metal and mining drives, Cranes, test benches, meeting the needs of critical electrification systems.
Utilities today seek to create and connect new sources of power generation to meet growing global demand, while also managing grid reliability, costs and regulatory factors.
Water is central not just to the economy, but to life. As a result, water treatment systems demand secure, dependable power to ensure process uptime. From the grid-connected substation to reliable electrical protection, control, and power quality metering, GE Vernova offers tailored solutions to keep critical plants operational and meet the unique needs of the water and wastewater industry.
As power systems become increasingly interconnected and complex, utilities need solutions that optimize energy transmission and management while improving reliability.
Data centers – and the information they store – are becoming increasingly integral to the way we live our lives every day. With rising demand also come rising costs. And more importantly, the information in these centers must remain secure while simultaneously accessible. We provide data centers with electrical infrastructure solutions from the input utility source to the IT server racks. This includes high-voltage switchgear and transformers, medium and low voltage electrical equipment, automatic transfer switches, switchboards, UPS systems, critical power PDUs, static transfer switches, and overhead busway. This chain of electrification products provides high quality and reliable products and services for the entire lifecycle of a data center.
The oil and gas industry is evolving at a rate never seen before, facing shifting pricing levels, ever-changing regulatory requirements, and increased environmental consciousness. Through reliable, safe, and innovative solutions and a holistic service offering, GE Vernova can help the energy sector thrive in this changing reality.
Modernizing and digitizing the distribution grid is imperative for utilities and customers to enhance power system stability and safety, while increasingly integrating distributed power and demand response.
The industry is changing. Simultaneously, so are your utility’s needs. Operational effectiveness, power stability, and critical asset management are key priorities – whether in pulp and paper, steel, or data centers. GE Vernova’s holistic portfolio of products and services are designed with reliability, innovation, and sustainability at the forefront, helping you face the energy transition with ease.
Mining companies require secure communications, efficient asset performance management, and dependable, innovative technology to protect their critical assets. GE Vernova offers a broad product portfolio to help you through each step of the mining process – safely and reliably.
Power transformers are critical for ensuring a sustainable supply of power to prevent outages. With the loss of insulation being irrecoverable, transformer failure risk can be minimized only if oil quality is maintained, moisture is controlled, temperatures are managed, incipient faults are detected and corrected, and an overhaul is conducted at midlife.
GE Vernova provides specialized technical services during the whole lifecycle of all high voltage transformers:
Power transformers are critical for ensuring a sustainable supply of power to prevent...
Services are performed by local trained and certified field service experts fully equipped for SF6 gas handling up to decommissioning and SF6 reclamation process. GE Vernova provides a wide set of services that allow fast response time and cost effective solution for optimized customer asset availability and life time.
Services are performed by local trained and certified field service experts fully...
GE Vernova’s innovative and high-quality services help maintain and optimize high-voltage electrical assets throughout their entire lifecycle. Leveraging the design and manufacturing knowledge of our skilled engineers, the customized service solutions ensure the substations and networks perform as planned. Field and technical experts deliver services for applications across the power system, keeping assets up-to-date, safe, reliable and efficient while improving customers’ return-on-investment.
GE Vernova’s Asset Lifecycle Management (ALM) services encompass a set of flexible solutions to optimize transmission and distribution electrical substations maintenance and replacement strategy. The services are designed to meet the customers desired level of outcome in terms of asset availability, risk management and total cost of ownership.
ALM services combine GE Vernova’s expertise in grid asset maintenance and reliability management with an innovative end-to-end set of digital applications and tools suitable for all types of asset independently of the original equipment manufacturer.
Whether its transmission, generation, distribution or industry and infrastructure electrical assets, GE Vernova provides the models and tools to enable customers to meet their company objectives in terms of:
Visit the Asset Lifecycle Management webpage to learn more about these services, as well as the ALM services tailored to HV/MV equipment including circuit breakers, instrument transformers, disconnectors, gas-insulated substations, transformers and systems.
GE Vernova recommends regular maintenance on equipment to ensure optimal operation and to reduce the risk of failure. Maintenance plans must be carried out by a qualified field services supervisor with the prerequisite technical levels. During warranty period, various maintenance levels must be conducted by the manufacturer on a regular basis related to the equipment. GE Vernova’s local teams can support its customers with emergency repairs, time-based, predictive and corrective maintenance.
Learn more about the specific maintenance and repair services available for HV/MV equipment, including circuit breakers, instrument transformers, disconnectors, gas-insulated substations, transformers and systems.
High voltage substations are very valuable grid assets, and are critical for grid reliability and availability. After decades of operation, grid operators may foresee risks of increasing failure rates in these assets due to electrical and environmental stress. Operators may also have needs for evolving power demand or for standard or technological enhancement.
GE Vernova supports the decision-making process by providing a cost efficient solution for substations and products requiring improved performance, or to resolve some obsolescence issues. GE Vernova’s engineered solutions are based on condition and life assessment of any high voltage equipment including third party original equipment manufacturer.
Training matters. It’s the key to enabling staff to maintain peak equipment performance in a safe environment. Gaining hands-on experience and enhancing technical skills will add long-term value to your business and career. You can rely on GE Vernova’s technical expertise to support your team’s development.
GE Vernova’s network of Technical Institutes offers a full range of training in electrical grid safety, operations and maintenance of our power equipment, protection and control, and network management solutions, near your location. These value-adding courses encompass all aspects of electricity from fundamentals to in-depth equipment knowledge. Trainees benefit from trainers’ expertise in techniques and field experience combined with pedagogy.
Learn more about our HV/MV technical training.
GE Vernova aims to deliver continuous field operational excellence through its broad service experts network. Providing the highest level of quality of services as well as the competence development of the technicians and supervisors is GE Vernova’s top priority. GE Vernova’s subject matter experts’ competencies, qualification levels and certifications are checked regularly in compliance with local regulations and strict internal GE Vernova standards. As a result, wherever our customers are located, GE Vernova provides the best field experts to ensure complete satisfaction.
Internal dielectric strength degradation is the main risk affecting the lifetime performance of an instrument transformer. Contributing to 70% of the failures, it can ultimately cause a fire or explosion that can damage nearby high voltage assets. The degradation can be due to overheating, short circuit, oil leakage from gasket deterioration caused by tough environmental conditions, or the humidity contained in oil-impregnated cellulose insulation.
Internal dielectric strength degradation is the main risk affecting the lifetime...
GE Vernova delivers materials and eco-design studies for high voltage solutions to accelerate insulation and environmental innovation. GE Vernova’s services provide the expertise and methods that enable new value to support customer engineering, sourcing, quality control and EHS activities.
The technical studies, tests and impact evaluations support:
Eco-Design
Inspections & Homologations
Investigation
Anti Corrosion
Material Selection
Solid Insulation
Liquid Insulation
Gaseous Insulation
The R&D studies support the development of many types of insulation material, provide corrosion and metallic material analysis and help reduce the environmental footprint of equipment and technologies. Type of materials supported:
Studies are delivered by GE Vernova’s Subject Matter Experts based in the Global Technology Center. The team is active in international working groups and delivers lectures at technical conferences including CIGRÉ, Matpost, IEEE, CEIDP, IEC.
The GE Vernova materials and eco-design team members have filed over 35 patents in the last 15 years and bring disruptive technologies to the industry, examples include:
g3, the environmental friendly gas to replace SF6 in high voltage switchgear
Biodegradable and vegetable oil for power transformers, which improves safety
Recyclable thermoplastic for gas-insulated substation
GE Vernova's DWatch performs permanent real time monitoring of the operational parameters of disconnectors and records all operating curves locally.
The DWatch also controls the speed of the live part during opening and closing in a specific and programmable manner for all disconnector types. These profiles can be easily set by internal dip-switches. Such control helps in always having a constant operating time in different conditions of power supply and load.
GE Vernova's DWatch performs permanent real time monitoring of the operational parameters...
Point-on-wave switching is a technique consisting in operating AC system switchgear /...
GE Vernova’s CBWatch is a compact, modular, online monitoring solution suitable for...
Power connectors join two or more conductors for the purpose of providing a continuous electrical path. GE Vernova offers tap, terminal, splice and non current carrying connectors.
The GE Vernova portfolio offers an extensive range of HV power connectors for substations. Several other types of connectors not mentioned are available, or can be specifically designed.
Power connectors join two or more conductors for the purpose of providing a continuous...
HYpact is a hybrid compact switchgear assembly that typically consists of circuit breakers, disconnectors, and earthing switches located in a common gas tank. Current and voltage transformers can be added and the standard SF6 to air bushings can be replaced with cable connectors. Its modular design allows for a large variety of different layout configurations and enables a more economical substation design.
GE Vernova Advantage
HYpact assembly enables more economical substation design and operation, with savings to be achieved in space consumption, preparation planning, transport and at-site installation, switchyard cost and maintenance. Operators also choose HYpact where space is ample to benefit from the long maintenance periods. Compared to conventional air insulated substations, the maintenance-free periods of substations using HYpact can be tripled or even quadrupled.
In addition to savings in space and maintenance, HYpact largely reduces the switchgear’s exposure to environmental influences, thus providing an economic alternative to gas-insulated substations in places being heavily polluted, or under extreme weather conditions.
Key Features
The HYpact hybrid compact switchgear assembly is uniquely suited for a variety of situations, including space constrained installations and use in polluted or seismic environments. In addition, it also qualifies for mobile applications, either installed on trailers or on skids.
Due to the low number of bushings and the avoidance of movable contacts, pure SF6 gas Hypact units perform well in harsh climates, even under heavy snow and ice load, or at temperatures as low as -60°C (GOST FK certification).
Benefits
HYpact is a hybrid compact switchgear assembly that typically consists of circuit...
GE Vernova's Generator Circuit Breakers (GCBs) are ideally suited for new and refurbished power plants from 50 MW to 1,500 MW and feature advanced technology with spring-spring-operated mechanisms. The comprehensive GCB portfolio provides solutions from generator circuit breakers without enclosure to customized solutions including disconnector, earthing switch, starting switch and instrument transformers.
For most utilities ensuring grid reliability, efficiency, and security is a primary concern. As the grid evolves and load profiles change, stresses are being put onto transmission and distribution networks, making the work of grid management much more challenging. Globally, utilities are facing many grid challenges and market condition changes including:
Utilities must respond to these challenges and generate energy economically and safely. They face additionally following business challenges:
GE Vernova offers utilities a reliable and robust solution to address the commercial and operational requirements with a comprehensive range of Generator Circuit Breakers (GCB) with advanced technology and 40+ years of deep domain expertise. GE Vernova is a world leader for GCB with 3,000+ installed breakers worldwide in applications including hydro, pump-storage, gas and steam turbines, combined cycle, nuclear and geothermal power plants from 50 MW to 1,500 MW.
Power plant owners must generate energy economically and safely with the highest availability of their equipment. Most operational managers recognize the need for reliable and robust generator circuit breakers. The modular diagram - which uses a generator circuit breaker compared to the block type diagram solution - has several advantages, which are summarized as following:
The design of the generator circuit breakers is compliant with IEC/IEEE 62271-37-013 standard and other relevant international standards. The following components are commonly used in the GCB range with proven robustness and reliability.
CBWatch3 is a universal and compact device suitable for any kind of HV circuit breaker.
Generator circuit breaker for power plants from 50 to 150 MW
Generator circuit breaker for power plants from 100 to 200 MW
Generator circuit breaker for power plants from 150 to 300 MW
Generator circuit breaker for power plants from 200 to 300 MW
Generator circuit breaker for power plants from 300 to 450 MW
Generator circuit breaker for power plants from 200 to 450 MW
Generator circuit breaker for power plants from 450 to 600 MW
Generator circuit breaker for power plants from 750 to 900 MW
Generator circuit breaker for power plants from 600 to 750 MW
Generator circuit breaker for power plants from 900 to 1000 MW
Generator circuit breaker for power plants from 700 to 1,500 MW
Modular Arrangement and Switching Devices for Pump Storage Operation and Protection
GE Vernova's solution for Pumped Storage Power Plant (PSPP) offers an integrated package of protection schemes, including generator circuit breaker, phase reverse disconnector, braking, starting and back-to-back switches.
Braking switch is designed to perform an electromagnetic braking of the generator by carrying out a circuit of the 3 phases, allowing to reduce the time of shutdown before being able to reverse the operation cycle.
The use of GCB increases the overall availability of the power plant. It also insures safe, reliable, economical operation and protection of the power plant.
Starting Disconnector and Back-to-Back switches are the mechanical isolation devices located on the generator and transformer sides of the GCB. These switches ensure busbars connection between units and allow starting in pumping mode for Pumped Storage Power Plant. SDS alone or combined SDS with back-to-back solution are available according to power plant layout.
Phase Reverse Disconnector Switch provides 3 phases closing in pumping or generation mode, it also makes breaking capability for active parts to ensure the safety and electrical insulation of the open device.
Based on manufacturing expertise and time-proven field experience, GE Vernova offers cost-effective and efficient solutions to help increase the life span of your generator circuit breakers and drastically reduce the risks of failure. Benefiting from GE Vernova’s innovative technical services will keep your equipment up-to-date, safe, reliable and efficient all along its lifecycle. From onsite assessment, periodic maintenance and mid-life overhaul to complete retrofit and emergency solutions, GE Vernova provides customized solutions for your generator circuit breaker according to its type, age, operating conditions and ratings.
Maintenance & Repair
Strategic Spare Parts Management
Emergency Support
GE Vernova's Generator Circuit Breakers (GCBs) are ideally suited for new and refurbished...
Electrification, a GE Vernova business, offers a comprehensive range of dead tank circuit breakers that support a voltage rating up to 550 kV, and are capable of carrying a continuous current up to 5,000 A. Our circuit breakers meet or exceed the latest IEEE/ANSI and IEC standards, including C2 and M2. They can be gang operated up to 245 kV, and Independent Pole Operation (IPO) is available at all voltage levels.
Utilities are heavily struggling with the decentralization of power generation and especially with the integration of renewable energy sources into the grid. Integration can conflict with existing modernization and optimization plans. Issues of reliability, safety, power quality and economics have to be taken into account when planning substations and choosing the right switchgear.
Additionally, power systems are already interconnected, highly complex networks that are susceptible to instability. Utilities face several challenges in managing and maintaining today‘s complex grid, including:
Overall, utilities are under intense scrutiny, by both regulatory agencies and the public, to prevent power system failures today, and in the future.
GE Vernova offers utilities very reliable high voltage circuit breakers with advanced switchgear technology to improve grid stability and increase the efficiency of the transmission system infrastructure. The role of circuit breakers is to protect electrical equipment and system infrastructure, by fulfilling critical operational and safety functions. In normal operation, they carry nominal load currents, and depending on the installation, switch various equipment such as lines or transformers.
GE Vernova's dead tank circuit breakers are developed based on the highest standards for performance, ratings, user convenience and reliability. Every circuit breaker model is thoroughly tested to meet or exceed the latest IEEE and IEC standards including Class C2, Class M2, fast TRV and high asymmetry.
Unique and Superior Design Provides Optimal Performance and Lower Total Cost of Ownership
Manufacturing Excellence to Ensure Highest Quality Standards
Extensive Research, Testing and Proven Field Experience Resulting in Enhanced Reliability
Optional Features for Enhanced System Compatibility, Digital Integration and In-House Expertise
GE Vernova's Dead Tank Circuit Breakers, the DT Series, supports system voltages from 38 kV to 550 kV and are designed for reliable performance, maximized safety and lower cost of ownership. The DT Series is designed to operate within extreme environmental conditions including high elevation, very low and high temperatures (-60 °C to +60 °C ), seismic zones, polluted areas and corrosive atmospheres.
DT1-38
Dead Tank Circuit Breaker for 38 kV / 40 kA
DT1-72.5
Dead Tank Circuit Breaker for 72.5 kV / 40 kA
DT1-72.5g-40
SF₆-Free Dead Tank Circuit Breaker for 72.5 kV / 40 kA
DT1-145g 63
SF6-Free Dead Tank Circuit Breaker for 145 kV / 63 kA
DT1-145R-40
Dead Tank Circuit Breaker with Pre-Insertion Resistors
DT1-145 and DT1-170
Dead Tank Circuit Breakers for 123 kV, 145 kV and 170 kV / 40 kA
DT1-145 63
Dead Tank Circuit Breaker for 123 kV and 145 kV / 63 kA
DT1-245P
Dead Tank Circuit Breaker for 245 kV / 40 kA
DT1-245P 63
Dead Tank Circuit Breaker for 245 kV / 63 kA
DT1-362
Dead Tank Circuit Breaker for 362 kV / 63 kA
DT2-550
Dead Tank Circuit Breaker for 550 kV / 63 kA
GE Vernova's DT Series is characterized by advanced self-blast interrupters, leak resistant cast aluminum enclosures and durable low energy mechanisms.
Interrupting Chamber
GE Vernovacircuit breakers use a proven innovative interrupter design with self-blast technology that significantly reduces the mechanical energy required to clear short-circuit currents. The interrupter design uses the arc energy to generate gas compression for efficient quenching of the arc itself.
As a member of the puffer family, the interrupter has two gas volumes within the chamber, one mechanical and one thermal. The design of the interrupter ensures that the circuit breaker will interrupt short-circuit fault current from low level faults to the full nameplate rating.
Spring-Spring-Operated Mechanism
GE Vernova has been developing and manufacturing spring-spring-operated mechanisms since 1938. The most recent state-of-the art evolution for these mechanisms is the FK3 range, which is used for all GE Vernova high voltage switchgear applications including dead tank, live tank, generator circuit breakers, GIS and hybrid solutions. Over 300,000 FK3 mechanisms are in operation worldwide. The FK3 low energy spring-spring mechanism provides the highest level of reliability with Class M2 performance for 10,000 no-load close-open operations without the need for routine maintenance. With a spring-spring-operated mechanism there are no pneumatics or hydraulics, ensuring safe, reliable and maintenance-free operation for the normal circuit breaker service life of 50 years or more.
CBWatch3 is a universal and compact device suitable for any kind of high voltage circuit breaker.
More Info
GE Vernova's investments in Research and Development (R&D) are significant, allowing utilities and grid operators to benefit from the latest technologies and innovations. The Center of Excellence for dead tank circuit breakers is located in Charleroi, PA (USA), where dead tank circuit breakers up to 550 kV and live tank circuit breakers up to 800 kV are assembled.
The production lines feature high degree of domestic content which can help to facilitate compliance with national requirements. In addition, the complete wiring and assembling of low voltage control cabinets and mechanism cabinets is done locally, resulting in greater flexibility to respond to utility needs.
Research and Development (R&D), manufacturing and commercial units are fully certified according to ISO 9001. This means that during the entire production process, all employees, all equipment and all of the company's operations are dedicated to the highest quality standards and permanent improvement.
The Advanced Production System (APS) is the framework for contemporary manufacturing excellence in all Electrification sites. It is based on lean tools for continuous improvement of safety, quality, cost and delivery.
APS brings together a wide range of best practices and standards in seven domains such as Basics, Environmental, Health & Safety (EHS), Supply Chain, Project Delivery, Manufacturing, and Quality & Leadership to create and sustain world class manufacturing excellence.
All dead tank circuit breakers are type tested in world class laboratories such as KEMA, CESI and CERDA, in full compliance with international standards such as IEEE, IEC, GOST and DL standards. Specific homologation processes (additional tests, specific reports) are provided as per customer requirements.
Following tests are performed according to the latest standards:
Dedicated project teams are located in all regions throughout the world. These on the ground teams provide support and expertise to assist customers during different project phases. Local field service teams are also available worldwide, providing immediate support, training and supervision.
As part of optimizing the maintenance and asset replacement strategies, GE Vernova employs stress assessment analysis, SF₆ monitoring and online condition monitoring to allow comprehensive centralized asset management.
Maximizing the life cycle performance of circuit breakers through the right maintenance strategy, strategic spare parts stock and toll-free 24/7 hotline.
GE Vernova has the technical expertise to deliver customized engineered solutions to extend the life of ageing equipment. Our Service Teams are experienced in solving obsolescence issues and overhauling substation equipment as required.
GE Vernova provides on site technical training such as modular and competence development training as well as e-learning and educational partnerships. These skills not only enhance team knowledge, but increase productivity.
Learn More
Leading SF₆-free Dead Tank Circuit Breaker for 72.5 kV Applications. The SF₆-free...
Leading SF₆-free Breaker with 63 kA Short-Circuit Current The SF₆-free DT1-145g rated...
Electrification, a GE Vernova business, offers a comprehensive range of dead tank circuit...